PoliGrout®35-GR, Rapid Grout Mortar

PoliGrout®35-GR, Rapid Grout Mortar

  • Product description
  • Technicial Specifications

Description of Product
PoliGrout®35-GR, is cement based one component, self compacting non-shrink rapid grout.

Fields of Application
-Construction of shear wall caps and column caps, 
-Fixing of pre-cast concrete elements, 
-Fixing of the turbines on the foundations, 
-Fixing of the generators, compressors and pumps on the foundations, 
-Fixing of the industrial machines on the foundations, 
-Fixing of the steel columns on the RC foundations, 
-Filling of the voids in the jacketing applications.

Features and Benefits
-Mixed with only water and can be applied easily. 
-High compressive strength. 
-High fluid consistency. 
-Free of bleeding.
-Resistant to water and weather conditions. 
-Perfect bonding to the concrete and steel. 
-Non-shrink.

Application Procedure
Preparation of Substrate
The concrete should be free of frost, curing membranes, waterproofing treatments, oil stains, laitance, friable material and dust. 

Mixing Ratio

PoliGrout® 35-GR

1 kg Powder

25 kg Bag

Water Quantity

0.14 - 0.16 liter

3.5 - 4 liter

Mixed Denisty

~ 2.20 kg/liter

Application Method
In the case of operating neigbour machines, a glass of water should be put on the grouting base and the vibrations caused by the environment can be observed. If  needed, surrounding machines should  be swicthed  off until  (10-12  hours in 20˚C) the grout sets. PoliGrout®35-GR should be poured directly  into the formwork or it should be pumped under pressure. Application thickness should be 1-4 cm. For preventing the possible air gaps in the formwork, pour the grout from single opening and let the air draining.  Use a steel hook for placing the grout under the plates and do not use vibrator. For thicker applications second layer of the mortar should be applied  in same way or consult to the POLİKROM 

COVERAGE
19.00 kg/m2 for obtaining 1 mm thick layer.

Watch Points
-During the application the substrate and ambient temperature should be between 5-30˚C. 
-Open areas should be protected from the rain, wind, etc. aggressive whether conditions during the first 24-48 hours after finishing repair.
-Cement based materials’ pot life and curing times vary depending on the relative humidity, substrate and ambient temperature. Reaction gets slow in low temperatures and it causes to extension on pot life and working time. On the other hand high temperatures speed up the reaction, which results to short pot life and working time. For full curing  of material, both the substrate and ambient temperature shouldn’t be under allowed application temperature. 
-Do  not  use  PoliGrout®35-GR in  case  of contacting to liquids with a PH under 5.5. 
-Do not use vibrator for placing the mortar. 
-In low temperatures (5˚C-10˚C) the following precautions should be taken;   
The product should be stored in warm    conditions,   
Hot water (30˚C-50˚C)  should be used for    mixing,   Grouting area should be heated and    protected from cold. 
-In high temperatures (25˚C-30˚C) the following precautions should be taken;
The product should be stored in cool    conditions, 
Cold water (0˚C-10˚C) and ice should be    used for mixing,

CLEANING OF TOOLS
After the application all tools should be cleaned with water. PoliGrout®35-GR can be cleaned with only mechanical abrasion after hardening.

STORAGE
Store in original container in cool (+5˚C ± 25˚C) and dry indoor conditions.
SHELF LIFE 
6 months under proper storage conditions after production date.
 

Product ChemistryMineral Fillers and Polymer Modified Cement
ColorGrey
Compressive Strength TS EN 196 (1 day) (7 days) (28 days)>30 N/mm2 >50 N/mm2 >60 N/mm2
Flexural Strength TS EN 196 (28 days)>8 N/mm2
Bonding Strength TS EN 1542 (28 days) to concrete to steel>2.0 N/mm2 >2.0 N/mm2
Application ThicknessMin. 10 mm Max. 90 mm
Application Temperature+5˚C ± 35˚C
Pot Life20 minutes
Fully Cured at 20˚C28 days
Elasticity Modulus TS EN 13412 (28 days)>20.000 N/mm2
Capillary Water Absorption (TS EN 13057)≤0.5 kg.m-2.hour-0.5
Service Temperature-30˚C ± 400˚C
Open Time to Pedestrian Traffic24 hours
.Typical values are obtained from the test results of 4x4x16 mortar prism in 23˚C and 50% relative humidity conditions. High temperatures shortens the curing and working time, lower temperatures extends the durations